Multifunctional display/operating device for KNX‚ with 320 x 240 pixel‚ 2.8″ LCD color display
V For the display and operation of at least 18 configurable room operator functions:
– Switching On/Off/Over and Pushbutton function (bell function)
– Shutter/blind/roller control
– Value transmission: 1 byte in %‚ 1 byte integer without prefix‚ 1 byte integer with prefix‚ 2 byte integer
without prefix‚ 2 byte integer with prefix
– Positively driven operation
– Scene control: Store and call up scene 8 bit‚ store and call up scene 1 bit
– Text display and warning and alarm indications
V Operation using touch screen and/or by turning/pushing rotary/push button
V RGB LED as orientation light or for signaling alarm indications
V Buzzer for acoustic alarm indication or as feedback when operating touch screen
V Integrated room temperature sensors
V Analysis and weighting of an external inside temperature sensor
V Room temperature control can be set as a two-point control and/or continuous-action control for
heating only‚ for cooling only‚ or for heating and cooling mode
V Operating modes that can be switched via KNX: comfort mode‚ pre-comfort mode‚ energy-saving
mode and frost or heat protection mode
V Local displaying of active operating modes or automatic or manual modes
V Local displaying of heating/cooling valve open‚ dew point alarm and open window
V Local switchover between automatic or manual mode‚ and between comfort‚ pre-comfort‚ energy-saving
and protection modes
V Local‚ time-adjustable extension of comfort mode
V The room temperature setpoint value for comfort mode can be set via a rotary button on the room
controller
V Basic room temperature setpoint value for comfort mode which can be set via the KNX
V Outdoor temperature-based tracking of temperature setpoint value in cooling mode
V Adjustable dead zone between the heating setpoint and the cooling setpoint for comfort mode
V Two-level heating or cooling
V Output of the control variable(s) either as an on/off switch command or as a positioning command in
the range of 0…100%
V Local displaying of manually set fan speed step or automatic speed input
V Fan speed step can be set via the rotary button or entered automatically by the controller
V Weekly scheduling program for controller operating modes and for 18 room operator functions
V At least 16 time switching points per function per weekday
V Display of date and time
V Selection of at least 4 different design templates as operator and display interface
V Local activation of a cleaning function to lock the touch screen and the rotary/push button
V Slot for a micro SD card for transferring firmware and configuration data
V incl. bus coupling unit (included in delivery)
V Bus connection via bus terminal
V Connection of the separate 24 V DC boost voltage‚ power consumption approx. 50 mA
V Flush-mounting device for mounting in a Ø 60 mm installation box‚ with screw fixing
Product Title Stock No. Product No.
Room Controller Contouch‚ incl. bus coupling unit‚ titanium white 5WG1204-2AB11 UP 204/11
Room Controller Contouch‚ incl. bus coupling unit‚ carbon metallic 5WG1204-2AB21 UP 204/21
Room Controller Contouch‚ incl. bus coupling unit‚ aluminium metallic 5WG1204-2AB31 UP 204/31
Room Controller Contouch‚ incl. bus coupling unit‚ piano black 5WG1204-2AB51 UP 204/51